Blue Prism
AIE02
Q1:
Which of the following ate valid steps to create a Blue Prism database? (select two)
☐
A
Using a Blue Prism device, create a direct database connection to connect to the server. use the in-product 'Create database' functionality☐
B
Using a Blue Prism device, connect to the Blue Prism Application Server, use the m-product 'Create Database' functionality☐
C
Using SQL Management Studio create a database, manually run the CreateScript provided by Blue Prism, then use the n-product 'Configure Database' functionality☐
D
Using SQL Management Studio manually run the CreateScript provided by Blue Prism to generate the database, then use the m-product 'configure Database* functionality.
Blue Prism
AIE02
Q2:
When starting a Runtime Resource using the /ssIcert switch, what reasons can prevent it from starting? (select two)
☐
A
If the name- on the certificate does not match the name (or correct format) of the Runtime Resource☐
B
If the thumbprint of the certificate is not for a valid certificate on the local device☐
C
If the certificate has expired or been revoked☐
D
If the certificate has not been issued by a certification authority that is trusted by device attempting to connect
Blue Prism
AIE02
Q3:
Which of the following which are common reasons why a Blue Prism Interactive Client is not be able to canned so an Application Server? (select three)
☐
A
f the Applicant Server service is not started☐
B
If Firewall prevent the Application Server from receiving traffic on the appropriate port☐
C
If the Application Server is configured to use Transport Encryption but the certificate cannot be validated☐
D
Invalid user credentials☐
E
A user is logged into Blue Prism on the Application Server
Blue Prism
AIE02
Q4:
Which of the following reasons would prevent the Blue Prism Server service from being started? (select four)
☐
A
It can't (md a BPServer exe profile with the name that it expects☐
B
It the BPServer exe profile is not configured with the expected encryption schemes☐
C
If the user that the server service is attempting to use cannot access the Blue Prism database☐
D
If there are no Blue Prism devices configured to connect to the server service.☐
E
There is a problem with the Blue Prism license Key in the environment☐
F
If the server service has nothing to process (eg if there are no schedules configured)
Blue Prism
AIE02
Q5:
When a Runtime Resource has been started using the /sslcert switch, why might 4 not be able to receive connections? (select three)
☐
A
If the name on the certificate does not match the name being used to connect to the Runtime Resource☐
B
If the thumbprint of the certificate is not for a valid certificate on the local device☐
C
If the certificate has expired 01 been revoked☐
D
If the certificate has not been issued by a certification authority that is trusted by the device attempting to connect☐
E
It the context user of the Runtime Resource does not have read-only access to the certificate's private key